34%34 Percent

Compare

Same material. Two atmospheres.

NASA burned the same cotton-fiberglass cloth in Saffire IV at 22% oxygen and normal pressure, then in Saffire VI at 31% oxygen and about half the pressure, close to Moon base air. Both fires are real measurements, side by side.

T+00:00

Left

22%

oxygen · 14.5 psi

Ready

This fire will keep burning

measured

Burn time

130 s

Heat release

3.1 kW

CO₂ rise

1.12 mmHg

CO rise

86 ppm

Measured: Saffire IV-1, SIBAL cloth at 22% O₂, 100 kPa. NTRS 20240002981 Table 2 (fuel-consumption calorimetry, average heat release).

Right

31%

oxygen · 7.85 psi

Ready

This fire will keep burning

measured

Burn time

112 s

Heat release

3.2 kW

CO₂ rise

1.14 mmHg

CO rise

120 ppm

Measured: Saffire VI-2, SIBAL cloth at 31% O₂, 54.1 kPa. NTRS 20240002981 Table 2.

What changes

−14%

Burn time, right vs left

+2%

CO₂ partial pressure (what crew limits use)

+40%

CO concentration in the cabin

At lower pressure the same cabin holds less air, so the fire's CO₂ concentration roughly doubled (1,390 → 2,800 ppm), while the CO₂ partial pressure that crew limits are based on stayed similar. The fire burned faster and left more carbon monoxide per cubic metre.

Saffire IV-1 heat release is an average from fuel consumption; Saffire VI-2 is a peak from oxygen consumption (NTRS 20240002981, Table 2). Gas rises are scaled to a 16.7 m³ cabin. Methods →